Rashtriya Ispath Nigam Limited (RINL) - Visakhapatnam

Inspection of more than 250 concrete & steel structures & chimneys for issuing stability certificate. Visual inspection and condition survey shall be done for the condition of all concrete or steel structural members and non-structural members , identify the distress if any, record all data of current status, analyse the data for each structure and give ratings to them based on  the current  status, identify the cause of distress and submit the report of categorization along with “Structural Stability Certification” with recommendations for interventions based on the category which is arrived at based on cumulative structural rating system. Condition survey, Inspection & Testing of about 14 kms of pipeline work and providing Stability certificate  

SAIL RORUKELA

Visual inspection, Structural stability Certification and Report submission for Caster#4 & Ladle Heating Furnace in SMS-II, Coke Oven Battery#2 Re- Building, Treatment System under Zero Liquid Discharge – 1

SAIL BOKARO STEEL PLANT

Visual inspection, condition & conducting more than 15 types non-destructive testing for 129 concrete structures, Silos, Chimneys, bridges including study of surface damages, cracks, flaking, coloration, local weaknesses, etc and their damage classification by using instruments like camera with flash light, magnifying glass, binoculars, gauge for crack width measurement, chisel and  Hammer, etc used. The visual inspection shall largely cover areas of high distress, cracks and their location, moisture, leakage, abnormal variations in Structure, algae and fungus growth, efflorescence, etc. Visual inspection would be documented in the form of worksheets, photographic records, distress over drawings, etc., Final analysis is done based on the identified causes of distress for repair interventions along with time lines

Garisson Engineer - Naval Base

Preparation and submission of self-sufficient detailed architectural drawings in AutoCAD for the Deficient Shopping Centre and allied facilities as per sound architectural practice/as per NBC norms/zonal specifications and as per approval conceptual line plans.

Design, detailing and submission of structural drawings as per architecture drawings for G+6 Deficient shopping centre, Pump House and UG Sump 2 Lakh Litres.

Preparation of detailed estimate, BOQ & yardstick of above mentioned structures as per SSR 2020 rates.

Chemeca Drugs Private Limited

Preparation of Architectural drawings, structural designing with STAAD analysis and detailing of individual drawings for the Production Block III and Design of foundation for PEB Warehouse.

Production block of G+1 structure which consists of 18 reactors of various capacities 16KL, 15KL, 12.5KL and 12KL in ground floor and two mezzanine floors consists of 5KL reactors each in first floor and planned for utilities of different tanks in terrace at various locations. 

Plinth Area: 1752 SQM

Porus Laboratories

Design adequacy check for additional loads of 2 No of Monorails for BPA in B block-(2 tons weight for system and 1 ton for Material capacity) with 3X 2=6 Ton weight in B block,  No Monorail for BPA in A block-(2 tons weight for system and 1 ton for Material capacity) with 3 Ton weight in A block, 1 No Monorail for 4NPI in A block-(2 tons weight for system and 0.8 ton for Material capacity) with 2.8 Ton weight in A block and 1 No of Monorail for 4NPI in A block-(2 tons weight for system and 0.8 ton for Material capacity) with 2.8 Ton weight in A block and submission of report for stability of the structure.

Parekh Plast

Visual inspection and condition survey shall be done for the condition of all concrete or steel structural members and non-structural members , identify the distress if any, record all data of current status, analyse the data for each structure and give ratings to them based on  the current  status, identify the cause of distress and submit the report of categorization along with “Structural Stability Certification” with recommendations for interventions based on the category which is arrived at based on cumulative structural rating system.